Water Sealed Dryers
from 5000 to 30,000 S.C.F.D.
|
 |
Piston Compressor Dryers
from 2,400 to 7,200 S.C.F.D.
|
 |
Special Purpose Dryers
200 - 850 S.C.F.D. and Portables
|
 |
ATS Transfer Systems
ATS-300 Transfer and Monitoring System, ATS-200Plus
|
 |
DC Series Compressors
DC-10, DC-12, DC-15, DC-20
DC-6Q, DC-10Q, DC-12Q, DC-15Q, DC-20Q
|
 |
Panels, Racks, Manifolds
Pipe Feed Panels "B" Meter Panels
Transducer Panels Manifolds Rack Assemblies
|
 |
Tubing and Fittings
Multi-Bundle Tubing Single Plastic Tubing
Nyla-braid Tubing Tube Fittings
|
 |
Industrial Dryers
DRY-PAK¬ Twin Tower Dryers ED Series Dryers
|
 |
Sales Reps
Contact information for the sales rep in your area.
|
 |
Tech Support
Our top notch technical support team.
|
|
|
Panels, Racks, and Manifolds
Dielectric's piston compressor
intermittent operating air dryers are the ideal unit for lower flow (less than 7200 S.C.F.D.) applications. These units utilize an oilless piston compressor in conjunction with a heatless drying system
to pressurize a storage tank and the air is then regulated to the field.
These air dryers are equipped with hour meters to help track run hours and assist with maintenance scheduling. In addition, all these models are equipped with a humidity alarm, preset at 2%RH at 70ÁF and a humidity bypass. Other alarm combinations vary
from model to model, contact the factory for specific details of each models alarm configuration.
The Model 5000 and 7200
intermittent operating air dryers are the ideal unit for lower flow (less than 7200 S.C.F.D.) applications. These units have two indepenent oilless compressors that can be operated individually or in a
"duplex" mode where the compressors alternate at each start-up. For added protection these units are equipped with an adjustable duplex timer that will start the standby compressor in the event that the on-line compressor doesn't pressurize the
storage tank within the preset time limit. This system works in conjunction with a heatless drying system
to pressurize a storage tank and the air is then regulated to the field.
Specifications
| Model |
5000CO |
7200CO |
Normal Output |
5000 SCFD |
7200 SCFD |
Maximum Output |
6000 SCFD |
8400 SCFD |
Electrical Requirement |
208/230V 60Hz-1Ph |
208/230V 60Hz-1Ph |
Operating Current |
11 Amp |
13 Amp |
Control Circuit Breaker |
2 Amp 2 pole |
2 Amp 2 pole |
| Height |
50 In. |
50 In. |
| Width |
29 In. |
29 In. |
| Depth |
22ü In. |
22ü In. |
| Weight |
300 lbs. |
335 lbs. |
The Model 2400 and 3200
intermittent operating air dryers are the ideal unit for small capacity applications that require air flows of up to 3200 S.C.F.D.. These models feature full alarm capability that can be monitored
a single "fault" alarm or the five alarm functions can be monitored individually. The oilless compressor operates on a pressure switch to pressurize a storage tank and the air is then regulated to the field. The electrical control panel uses
all solid state components for increased reliability and ease of service.
Specifications
| Model |
2400CO |
3200CO |
Normal Output |
2400 SCFD |
3200 SCFD |
Maximum Output |
3500 SCFD |
4100 SCFD |
Electrical Requirement |
115V 60Hz-1Ph |
115V 60Hz-1Ph |
Operating Current |
11 Amp |
13 Amp |
Control Circuit Breaker |
1 Amp 2 pole |
1 Amp 2 pole |
| Height |
47 In. |
47 In. |
| Width |
17Õ In. |
17Õ In. |
| Depth |
17Õ In. |
17Õ In. |
| Weight |
155 lbs. |
175 lbs. |
|
|
Piston Compressor Air Dryer
Model 5000/7200 Air Dryer
Model 2400/3200 Air Dryer
|